Category |
Specification |
|
Model |
EP-UPS2000UU2IE2-UK |
|
Capacity |
2000 VA / 1200 W |
|
Topology |
Line Interactive |
|
Form Factor |
Tower |
|
Input Voltage |
230 V AC (nominal) |
|
Input Voltage Range |
140 – 300 V AC (or 140–290 V AC) |
|
Input Frequency |
50/60 Hz (auto-sensing) |
|
Input Connection |
UK Plug |
|
Output Voltage |
230 V AC ±10% (battery mode) / ±7% to +15% (some sources) |
|
Output Frequency |
50/60 Hz ±1 Hz (battery mode) |
|
Output Waveform |
Simulated Sine Wave |
|
Output Connections |
2 x UK sockets + 2 x IEC C13 sockets (4 universal outlets total) |
|
AVR |
Built-in Boost and Buck Automatic Voltage Regulation |
|
Transfer Time |
Typical < 4–6 ms |
|
LCD Display |
Yes (shows input/output voltage, battery level, load, etc.) |
|
Battery |
2 x 12 V / 9 Ah sealed lead-acid, maintenance-free |
|
Battery Recharge Time |
6–8 hours to 90% capacity |
|
Typical Runtime |
~10–18 minutes at typical PC load (depends on exact load) |
|
Cold Start |
Yes |
|
Communication |
USB port + Monitoring & Control Software (input/output voltage, load, battery status, logs, auto-shutdown, email notifications) |
|
Protection |
Overload, short circuit, surge, intelligent battery management (float charging) |
|
Noise Level |
Low (fan-equipped) |
|
Operating Temperature |
0°C to 40°C |
|
Humidity |
0–95% (non-condensing) |
|
Warranty |
2 years (unit), 1 year (battery) |